SKU: 20965127186

Preferred Power Products P3 P3PC-8

Sale price$55.10 Regular price$61.22
Save 10%

Pay in installments of $15.30 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 16 - Jul 21

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Preferred Power Products P3 P3PC-8Power Distribution Board 8 Output Access Control Preferred Power Products P3 P3PC 8 Eight Output Power Control Board Access Control Power Controler Description: The P3PC 8 is multi output programmable power distribution module that converts one 12 24 VAC VDC voltage input to eight independently controlled power limited outputs. The outputs can also be configured as dry for C contacts. The outputs can be activated by an open collector sink or normally

» Power Distribution Board
» 8 Output - Access Control

Preferred Power Products P3 P3PC-8

Eight Output Power Control Board - Access Control Power Controler

Description:

The P3PC-8 is multi-output programmable power distribution module that converts one 12/24 VAC/VDC voltage input to eight independently controlled power limited outputs. The outputs can also be configured as dry for “C” contacts. The outputs can be activated by an open collector sink or normally open dry trigger input from an access system, card reader, keypad, push button, PIR, etc.

Outputs can operate in either Fail-Safe or Fail-Secure modes and will power magnetic locks, electric door strikes, magnetic door holders, etc. It can be powered by either one common source or by two independent sources, one for board power and the other for accessory power.

The FACP interface can trigger emergency exit, monitoring HVAC shut down, elevator recall or other auxiliary devices. The Fire Alarm disconnect can be configured for all affected or 50/50 mode. The P3PC-8 has numerous applications for Access Control Systems that require individually protected outputs that switch independently

Features:

  • Eight access control system trigger inputs. Options include either eight (8) normally open (NO) inputs, eight (8) open collector sink inputs or any combination.
  • Eight independently controlled outputs. Options include either eight (8) fail - safe and/or fail secure power outputs, eight (8) dry form “C” 5amp rated relay outputs or any combination.
  • Main fuse is rated at 10AMPS.
  • Output fuses rated at 3AMPS.
  • Handles up to 28VAC/24VD.
  • Eight (8) auxiliary power outputs (un-switched).
  • Red LED’s indicate outputs are triggered.
  • Fire alarm disconnect (latching or non-latching).
  • Green LED indicates when FACP disconnect is triggered.
  • Feature removeable terminal blocks for easy installation.
  • FACP output relay (form “C” contact rated @ 1AMP
  • 28VDC not evaluated by UL).
  • Board dimensions: 4.5” (L) x 8” (W) x 1.625” (H).
  • Lifetime Warranty

Related Products

  • P3PC-8-LE: P3PC-8 and large enclosure; dimensions 13” (H) x 15.5” (W) x 4.5”(D)

Install Instructions

NOTE: All installations to be performed by a qualified personal in accordance with NEC and local code

1. Mount P3PC-8 in desired location/enclosure. Note: Keep power limited wiring separate from non-power limited wiring (115VAC / 60Hz Input, Battery wires). Minimum .25” spacing must be provided. Carefully review: Terminal Identification Table. Typical Application Diagram LED Diagnostics. Hook-up Diagrams

2. Power supply input: The P3PC-8 can be powered with one (1) power supply which will provide power for both board operation and the locking devices or two (2) separate power supplies, one (1) to provide power for the board operation and the other to provide power for the locking devices. Note: The input power can be either 12 to 24 volts AC or DC (.5amp @ 12volt, .22amp @ 24volt current consumption with all relays energized.

(a) Single power supply input: If the P3PC-8 and the locking devices are to be powered using a single power supply, connect the output (12 to 24 volts AC or DC) to the terminals marked [- Control+].

(b) Multiple power supply inputs : When the use of two power supplies is desired, jumpers J1 and J2 (located to the left of the power/control terminals) must be cut. Connect power for the P3PC-8 to the terminals marked [- Control +] and connect power for the locking devices to the terminals marked [- Power +]. Note: When using DC power supplies

polarity must be observed. When using AC power supplies polarity need not be observed.

Note: For UL compliance the power supplies must be UL Listed for Access Control Systems and accessories.

3. Output hookup options: The P3PC-8 will provide either eight (8) powered (switched and/or auxiliary), eight (8) form “C”, or any combination of both powered and form “C” outputs.

(a) Switched Power outputs: Connect the negative (-) input of the device being powered to the terminal marked [COM]. For fail-safe operation connect the positive (+) input of the device being powered to the terminal marked [NC]. For fail-secure operation connect the positive (+) input of the device being powered to the terminal marked [NO].

(b) Form “C” outputs: When form “C” outputs are desired the corresponding output fuse (1-8) must be removed. Connect negative (-) of the power supply directly to the locking device. Connect the positive (+) of the power supply to the terminal marked [C]. For fail-safe operation connect the positive (+) of the device being powered to the terminal

marked [NC]. For fail-secure operation connect the positive (+) of the device being powered to the terminal marked [NO].(c) Auxiliary Power outputs (un-switched): Connect positive (+) input of the device being powered to the terminal marked [C] and the negative (-) of the device being powered to the terminal marked [COM]. This output can be used to provide power for card readers, keypads etc.

4. Input trigger hookup options:

(a) Normally Open [NO] input trigger: Inputs 1-8 are activated by normally open or open collector sink inputs. Connect devices (card readers, keypads, request to exit buttons etc.) to terminals marked [IN] and [GND].

(b) Open Collector Sink inputs: Connect the access control panel open collector sink positive (+) to the terminal marked [IN] and the negative (--) to the terminal marked [GND].

5. Fire Alarm Interface: A normally closed [NC], normally open [NO] or reversal of polarity input from a fire alarm control panel (FACP) will trigger all outputs, except when the independent mode option is selected.

6. Independent output mode: (eight (4) outputs with FACP disconnect with or outputs without FACP disconnect). To

program the independent mode set switch to the Fail Safe or Fail Secure position. In this mode of operation Fail Safe will be affected when the fire alarm interface is triggered and outputs Fail Secure will remain unaffected.

(a) Normally Open [NO] input: Connect the normally open FACP trigger input to the terminals marked [+ INP] and [T].

(b) Normally Closed [NC] input: Connect the normally closed FACP trigger input to the terminals marked [+ INP -] and install a jumper across the terminals marked [+ INP] and [T].

(c) Signaling Circuit input trigger: Connect the positive (+) and negative (-) from the FACP signaling circuit to the terminals marked [+ INP -]. Connect the FACP EOL or next signaling device to the terminals marked [+ RET --] (polarity is referenced in an alarm condition). Jumper J3 must be cut.

6. FACP dry contact output: Connect desired device to be triggered by the P3PC-8’s dry contact output to the terminals marked [NO] and [C] FACP for normally open output or the terminals marked [NC] and [C] FACP for normally closed

Product Downloads:

P3PC-8 Spec Sheet

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 20965127186

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.6 ★★★★★
Based on 7 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
M
Verified Purchase
Mystery Fan
Draper, US
★★★★★ 3
Not great at cooling
Size: Queen (2 Count), Color: Original White (Cooling)
Each pillow cover has 2 sides, one marked for cooling, and the other a different fabric. The cooling side is about the same effectiveness as having a silk or satin pillow cover. It's only cool when you first touch it. The cooling side doesn't seem to absorb or wick moisture, so if you are sweaty - it keeps the moisture in place. You'll definitely want a regular pillow case over the pillow cover. In fact, if you suffer from night sweats, the non-cooling side is actually more comfortable. The pillow fill is ample, and simple to squish around for more support for your neck, etc. Think bean bag. But it will retain your impression after use. I find I need to do as I did when I had down pillows - give it a few good shakes in the morning when I make the bed to get it evened out for the coming night. In all, it is a well-made and comfortable pillow to sleep on, but it does not excel in cooling.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 29, 2026
C
Verified Purchase
Carol C
Lexington, US
★★★★★ 5
excellent pillows i bought two sets!!
Size: Firm Queen (2 Count), Color: Original White (Cooling)
I ordered these for my son who has neck issues and has gone through so many pillows trying to find one that he liked. They’re heavy, so i was worried that they might be “too” heavy to be able to sleep on comfortably, so I ordered a second set, one firmer than the other (just in case) and gave him a set for Xmas and he loved the first set so much without even trying the less firm ones.He also needs the cooling factor and these offered that, too. They are filled with pieces of memory foam (tons of it) and each pillow can be modified by removing some of the foam. The covers are beautiful, high quality fabric with a zipper so ts easy to remove or replace the foam pieces. The size is perfect and they keep their shape. I kept the second set i ordered rather than returning them and i love the pillows. I actually modified two by removing some of the foam pieces. I kept the foam pieces in a zippered pillow protector and i can always adjust mine when or if i need to. 1000% love these.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 22, 2026
A
Verified Purchase
Asha
Phoenix, US
★★★★★ 5
The Perfect Firm Pillow l
Size: Queen (1 Count), Color: Original White (Cooling)
It is everything it claims to be, cool, comfortable and strong. I got this for my husband first, he loves it and then got one for my son, he uses it to support his knees and has been sleeping much better since then. They both needed a firm pillow that is not super soft, firm but not achy. Finally found the perfect one.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 6, 2026
M
Verified Purchase
Mopardodgegirl
Natrona Heights, US
★★★★★ 5
It works! Quality pillow.
Size: Standard (1 Count), Color: Original White (Cooling)
This does actually provide a cooling effect, and it's very comfortable! The accompanying literature is helpful too. I believe this to be a quality pillow for the price.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 2, 2026
J
Verified Purchase
jin
Grantham, US
★★★★★ 5
Most comfortable pillow I’ve ever slept on
Size: Queen (1 Count), Color: Crescent White(cooling)
This is the most comfortable pillow I have ever slept on. It doesn't mash down like other pillows. Cradles my neck perfectly plus it’s cool. I broke my neck a couple of years ago and this pillow feels very good and comfortable. Definitely recommend to everyone. Ive used it since May and it’s retained its shape.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 6, 2026

recommand products