SKU: 22506709963

Overcurrent Protection-NEC Article 240 and Beyond

Sale price$85.50 Regular price$95.00
Save 10%

Pay in installments of $23.75 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 31 - Aug 5

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Overcurrent Protection-NEC Article 240 and BeyondThis is a single license Digital eBook PDF File that is downloadable, and password protected eBook Description An overcurrent is caused by a short circuit, ground fault, or an overload. A short circuit may be hundreds or even thousands of times above the normal operating current. This type of fault may be an arcing fault between ungrounded conductors or between an ungrounded conductor and a grounded (usually, a neutral) conductor, a line to line

This is a single license Digital eBook PDF File that is downloadable, and password protected

 

 

eBook Description

An overcurrent is caused by a short-circuit, ground-fault, or an overload. A short-circuit may be hundreds or even thousands of times above the normal operating current. This type of fault may be an arcing fault between ungrounded conductors or between an ungrounded conductor and a grounded (usually, a neutral) conductor, a line-to-line arcing fault may produce a current of 74% of a 3-phase bolted fault. A line-to-neutral arcing fault will be somewhat less. A line-to-line bolted fault, the equivalent, of the conductors bolted together, may be up to 100% of the available short-circuit current. A line-to-neutral bolted fault may be in excess of 100% of the 3-phase bolted fault at the source, but considerably less downstream. A ground-fault, that is, the equivalent of a connection between an ungrounded conductor and the equipment grounding system, will produce a current that may be 38% or higher of the 3-phase bolted fault current. These types of faults are typically arcing faults which normally are intermittent in nature. That is, they strike and restrike over time and may produce a short-circuit fault due to insulation damage. Once again, a line-to-equipment ground fault near the source may produce a fault current of over 100% of the 3-phase bolted fault, but considerably less downstream. An overload typically ranges from one to six times the normal current, and are normally caused by motor starting currents or transformer magnetizing currents. These conditions are of such short duration that the circuit components are not damaged. This book has a detailed analysis of these types of faults, along with explanations and examples of the various types of overcurrent protective devices to assure proper protection. This volume has extensive information on the application of overcurrent protection for conductors and equipment. The reader will be able to calculate fault currents as well as establishing the short-circuit withstand rating of conductor insulation and to determine the appropriate type of overcurrent devices based on circuit conditions. In addition, determining ground-fault currents for the purpose of selecting the proper size of equipment grounding conductors to establish an effective ground-fault current path is discussed in detail."

 

Author: Gregory P. Bierals, President, Electrical Design Institute, LLC
e-ISBN: 9788770226202


Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 22506709963

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.3 ★★★★★
Based on 26 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
V
Verified Purchase
VCG
Omaha, US
★★★★★ 3
You get what you pay for…
Color: Beige, Size: 6 Panel-132'' Wide
Inexpensive - Cheap looks and construction
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 16, 2025
S
Verified Purchase
sydney b.
Dallas, US
★★★★★ 5
Very light weight, will
Color: Beige, Size: 6 Panel-132'' Wide, Color: Beige, Size: 6 Panel-132'' Wide
Easy to put together, nice privacy, great height!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 15, 2025
E
Verified Purchase
E. V.
New York, US
★★★★★ 4
Versatile!
Color: Grey, Size: 8 Panel-176'' Wide
Screen is more flexible than photo but folding it flat is challenging because of the supporting feet. I like the length of the screen; it divides a room in two, providing privacy and a walkway to back door. The screen can also be wrapped around the foot and one side of a queen size bed for privacy.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 25, 2026
B
Verified Purchase
Barbara Miles
Massapequa, US
★★★★★ 5
Room divider
Color: Black, Size: 8 Panel-176'' Wide
Enjoy it it’s beautiful breath taking
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 15, 2026
V
Verified Purchase
Val
Charlottesville, US
★★★★★ 5
True to Description
Color: Black, Size: 4 Panel
Love it!! I bought it for privacy while the nurse is dressing my dad. There were several colors black matched the decor . It blocked the sunlight and street lights. Durability and quality very good. Easy closure when not in use. Lightweight. No assembly needed
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 29, 2026

recommand products