SKU: 71498054657

Rat IL17B ELISA Kit

Sale price$155.71 Regular price$173.01
Save 10%

Pay in installments of $43.25 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 10 - Aug 15

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Rat IL17B ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.

Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing.

Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed.

Cell Lysis Buffer: Gently wash adherent cells with ice-cold PBS, then trypsinize and collect cells by centrifugation at 1000×g for 5 minutes. Suspension cells can be collected directly by centrifugation. Wash collected cells three times with ice-cold PBS and resuspend in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freeze-thaw cycles or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and remove the supernatant for analysis.

Cell Culture Supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for analysis or store at -20°C or -80°C, avoiding repeated freeze-thaw cycles.

Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 1000 pg/mL). Then dilute to the following concentrations: 1000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL, 31.25 pg/mL, 15.625 pg/mL, and 0.0 pg/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each tube. Pipette 500uL of the 1000 pg/mL standard working solution into the first EP tube and mix thoroughly to make a 500 pg/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit utilizes a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with Interleukin 17B (IL17B) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by peroxidase (HRP) catalysis and to yellow by acid. The intensity of the color is positively correlated with the amount of Interleukin 17B (IL17B) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Rat
Synonym Rat Interleukin 17B ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background IL-17B (interleukin 17B) is a protein-coding gene. Diseases associated with IL-17B include leukoma and keratitis 1. Pathways involved include the aryl hydrocarbon receptor pathway and the IL-17 family signaling pathway. Gene ontology data associated with this gene include cytokine activity, and an important homolog of this gene is IL17D. The interleukin 17 family (IL17 family) is a family of proinflammatory cystine knot cytokines. They are produced by a group of T helper 17 cells called T helper cells in response to IL-23 stimulation. The IL-17 family includes IL17A, IL-17B, IL17C, IL17D, IL17E, and IL17F. Each member of the IL-17 family has a distinct cellular expression pattern. IL-17B is expressed in some peripheral and immune tissues.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 15.6-1,000pg/mL
Applications Serum, plasma, tissue homogenate, cell lysate, cell culture supernatant and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 71498054657

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 13 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
K
Katrina Rhodes
Belleville, US
★★★★★ 5
Nice divider, serves it's purpose well!
Size: 3 Panel 12FT W
This room divider worked out very well for what I needed. I wanted a simple way to create a little more privacy and separation in a larger room without doing anything permanent, and this divider was an easy solution. The panels provide good coverage, and the black color gives it a clean, modern appearance that blends in nicely with different décor styles. Assembly was fairly straightforward, and once set up, the wider feet helped keep the divider stable on the floor. I was especially happy with how flexible the panels are to arrange. You can keep it mostly straight, angle it around furniture, or create a more enclosed private space depending on the layout you need. The material allows light to filter through slightly while still offering a noticeable sense of privacy. I’ve used it for separating a workspace area, but it would also work well in bedrooms, apartments, dorms, studios, or shared living spaces. Another plus is that it can be folded and moved without too much effort when you want to change the setup. Overall, this divider delivers a good balance of functionality, portability, and appearance. It’s a practical option for anyone needing temporary room separation without installing permanent walls or curtains.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 26, 2026
J
Jamie K.
Belleville, US
★★★★★ 5
Perfect for Adding Privacy to a Piano Studio
Size: 2 Panel 8FT W, Size: 2 Panel 8FT W
I Ordered the 2 Panel version which is way too big for my needs... that's on me. So keep in mind that the picture shows a fabric made for two panels only being used on one and hence it is not pulled tight; it would pull tight and not be so wrinkly if it was set up properly as two panels. The metal pools that make up the panels seem to be well made, stable, and of good quality. They were very easy to put together and they stand up tall with plenty of height. The appearance of it with the fabric on it isn't as elegant as it could be, but it still looks good enough. The material is plenty solid, not allowing light through it, and thereby making a solid barrier. I am using it to block the view out the studio door when a student is sitting at the piano to avoid distractions from the hallway. It will allow a student to enter the studio with our distracting the student who is at the piano.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 18, 2026
J
Just Me
Bozeman, US
★★★★★ 5
Room Divider That Gives Instant “This Is a Separate Space Now” Energy
Size: 3 Panel 12FT W
The Siebwin 3 Panel Folding Privacy Screen is surprisingly effective at changing the feel of a room without requiring construction, commitment, or somebody yelling about load bearing walls. The 12 foot width gives a substantial amount of coverage, making it useful for creating privacy, dividing open areas, blocking visual clutter, or setting up temporary sections within larger rooms. This saved us a ton of time and money in our new studio and enabled us to create a kitchen and office in one room. The wider feet make a huge difference because flimsy room dividers that collapse every time someone exhales too aggressively are deeply annoying. This one feels more stable and grounded once positioned. The folding design makes it easy to move around or adjust depending on the space, and it folds down relatively compactly when not in use. It is basically the introvert curtain wall of dreams. The material has a clean, neutral look that blends well into different room styles without screaming “temporary office cubicle panic.” It works well for apartments, studios, shared spaces, dressing areas, or simply hiding the mountain of chaos you swear you are going to organize tomorrow. Practical, portable, and refreshingly easy to use without turning setup into a three hour emotional event.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 16, 2026
S
Skeetre
Omaha, US
★★★★★ 4
It's 2 panels holding 1 big privacy screen. Can't use as 2 separate 4' panels, but works great.
Size: 2 Panel 8FT W
This 2 panel privacy screen works well. Assembly was very straight forward, with easily labeled tubes. My son and I had it together in about 10 minutes, which was probably 3 minutes of me telling him to quit playing around and hand me the parts. It feels very sturdy, not likely to fall over or anything. The material fits well, with the Velcro being very strong. Measurements are all very accurate, with all pieces attaching properly. We have a similar privacy screen at work that we have to try and stretch out because the top and bottom Velcro doesn't fit quite right... this model does not have any issues though. The material is thin and light weight, but solid black so that you can't see anything through or behind it. I definitely think it's a great deal for the money. What I think would have given it 5 stars though, is if you had 2 totally separate 4' panels instead of 2 panels with one big screen. It really wouldn't cost any extra to make it so that the screen was in 2 pieces and you could use it as 2 separate panels instead of having to use it as one big panel. It says 2 panel folding privacy screens, but it's really one big one that folds in the middle.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 25, 2026
B
Verified Purchase
Bri M.
Houston, US
★★★★★ 5
Flat Plug = Game Changer
Size: 6 Ft(2 prong plug), Color: Black
This is exactly what I needed to clean up my space. The flat plug sits flush against the wall, the long cord gives flexibility, and having multiple outlets + USB ports keeps everything in one place without the mess. It’s a 3 to 2 plug for homes that the electrical hasn’t been updated to 3 prong plugs. It feels solid, not cheap, and the surge protection adds that extra peace of mind. Perfect for a clean, organized setup that actually works.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 24, 2026

recommand products