Pay in installments of $46.03 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 29 - Aug 3
For Your Every Summer RSVP, with Code: SUMMER15
Description
Mouse CX43 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20
Product Specification
| Usage |
Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37℃ constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant and centrifuge at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing. Cell Supernatant: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse the tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed. Preparation before testing: 1. Please remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Preparation of gradient standard working solution: Add 1mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, and then gently mix (concentration is 10ng/mL). Then dilute to the following concentrations: 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.3125ng/mL, 0.15625ng/mL, and 0ng/mL. Serial dilution method: Take 7 EP tubes and add 500uL of universal diluent to each tube. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this step to mix thoroughly. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details. 3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit utilizes a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP enzyme conjugate are sequentially added to microwells pre-coated with a CX43 capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by HRP peroxidase and to yellow by acid. The intensity of the color is positively correlated with the amount of CX43 in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Mouse | |||||||||||||||||||||||||||||||||
| Synonym | Mouse CX43 ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Gap junction alpha-1 protein (GJA1), also known as connexin 43 (Cx43), is encoded by the GJA1 gene on chromosome 6. As a connexin, GJA1 is a component of gap junctions, enabling gap junctional intercellular communication (GJIC) between cells to regulate cell death, proliferation, and differentiation. Due to its functions, GJA1 has been implicated in numerous biological processes, including muscle contraction, embryonic development, inflammation, and spermatogenesis, as well as diseases including ophthalmopathy (ODDDD), cardiac malformations, and cancer. GJA1 is a 43.0 kDa protein composed of 382 amino acids. It contains a long C-terminal tail, an N-terminal domain, and multiple transmembrane domains. The protein crosses the phospholipid bilayer four times, exposing its C- and N-termini to the cytoplasm. The C-terminal tail, consisting of 50 amino acids, includes sites for post-translational modifications, as well as binding sites for transcription factors, cytoskeletal elements, and other proteins. Therefore, the C-terminal tail is central to regulating functions such as pH gating and channel assembly. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.156-10 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Serum, plasma, cell supernatant, tissue homogenate, etc. |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.6 ★★★★★
Based on 7 reviews
Sort
Product Reviews
★★★★★ 5
Used for a year.
Color: Black
Had this in a back pack for a year and wow. The dirt collected is kinda shocking. I will buy more of these for different bags!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 21, 2026
★★★★★ 5
Fun little gadget we never knew we needed.
Color: Pink
Who knew keeping our bags and purses could be so easy. Easy to clean once it does it's "job". Doesn't take up much room and works like a charm
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 31, 2026
★★★★★ 3
Mixed Results - Sauberkugel Clean Ball Review
Color: Bag Petrol
I purchased the Sauberkugel Clean Ball in Teal to help keep my bags clean from dust, dirt, and crumbs, and while it had some positive aspects, I can only give it a moderate 3-star rating due to a few shortcomings.
On the plus side, the concept of the sticky inside ball is ingenious and showed promise. It did manage to pick up some dust and small particles (including glitter) from my purse which was a relief. The teal color is cute and made it easier to spot in a bag.
However, there were some limitations that affected its overall effectiveness.
*It seemed to struggle with picking up certain types of debris, particularly larger crumbs, heavier dirt, and ever some larger glitter/confetti pieces. This inconsistency was a bit disappointing as I had hoped based on the ads for it to be much more effective.
*Another major issue I encountered was the difficulty of opening and cleaning the ball. The design was supposed to make it relatively easy to open and clean (as the ads lead me to believe). However I was unable to get the ball unlatched - which made it quite challenging to clean fully. It was frustrating to wrestle with the ball and being unable open to clean it out fully.
In summary, while the Sauberkugel Clean Ball had its merits and did manage to capture some unwanted particles, it fell short in terms of consistency and ease of use. The struggle to open and clean the ball was a significant drawback for me.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 29, 2023
★★★★★ 5
Great item, totally worth it.
Color: Black
I've used this for over a year now in my nice work purse to keep those tiny dirt particles from who-knows-where (you know the ones I mean!) from mysteriously getting in the bottom of of it. It rolls around easily in its plastic case either naturally (without getting goopy or leaky) or rolled by hand. Handiest thing I've ever bought to help keep my purse clean!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 23, 2025
★★★★★ 5
Extremely helpful keeping remotes in order
Color: Blue, Size: Small
Nice quality remote control holder, makes it easy to find what you need, organized life is an easier life to live ! Great price too and it looks good ! This was a great little buy, I brought one for my Mom and another for the guest bedroom.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 18, 2025
recommand products
ARP Ford Coyote 5.0L Balancer Bolt Kit - 156-2502
42.38
Spec 06-09 Mazda MX-5-Miata 2.0L 6sp Stage 1 Clutch Kit - SZ201
192.60
Perrin 08+ Subaru Black Upper Radiator Bracket Set - PSP-ENG-521BK
69.70
xTune Chevy Silverado 99-02 / Chevy Suburban/Tahoe 00-06 Amber Bumper Lights Euro CBL-CS99-E-AM - 5014764
52.00
Spec 06-09 Ford Fusion 2.3L / 06-09 Mazda MX-5/Miata 2.0L 5sp Stage 2+ Clutch Kit - SZ133H
238.50