SKU: 32349616917

UniOne® TR-FRET Human BCL-XL/CRBN PROTAC Binding Kit

Sale price$981.00 Regular price$1090.00
Save 10%

Pay in installments of $272.50 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 24 - Aug 29

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

UniOne® TR-FRET Human BCL-XL/CRBN PROTAC Binding KitProduct Specification Host Human Stability & Storage 80 Background The assay kit employs homogeneous time resolved fluorescence (TR FRET) technology to measure the interaction between the DDB1 CRBN complex and BCL XL mediated by the molecular glue XZ739 and test compounds. This method enables a simple, rapid, and high throughput screening of small molecules capable of mediating the interaction between the DDB1 CRBN complex and BCL XL. As shown in the

Product Specification


Host Human
Stability & Storage

-80℃

Background

The assay kit employs homogeneous time-resolved fluorescence (TR-FRET) technology to measure the interaction between the DDB1/CRBN complex and BCL-XL mediated by the molecular glue XZ739 and test compounds. This method enables a simple, rapid, and high-throughput screening of small molecules capable of mediating the interaction between the DDB1/CRBN complex and BCL-XL.

As shown in the figure below, the interaction between DDB1/CRBN and BCL-XL is detected using a Eu-labeled anti-Tag1 antibody (TR-FRET donor) and an acceptor-labeled anti-Tag2 antibody (TR-FRET acceptor). The molecular glue XZ739 mediates the interaction between DDB1/CRBN and BCL-XL, bringing the donor and acceptor antibodies into proximity. Excitation of the donor antibody triggers fluorescence resonance energy transfer (FRET) to the acceptor antibody, resulting in a specific emission signal at 665 nm. This signal is proportional to the extent of interaction mediated by XZ739 with DDB1/CRBN and BCL-XL. The homogeneous assay is simple to perform and requires no washing steps.

Components

Here is the translated content in English while preserving the original formatting:```html

Component

Concentration

100T

500T

2500T

10000T

Storage Temperature

Tag1-CRBN protein

50×

8μL

40μL

200μL

800μL

-80℃

Tag2- BCL-XL protein

100×

5μL

20μL

100μL

400μL

-80℃

XZ739

4mM

5μL

5μL

25μL

100μL

-80℃

Anti-Tag1 Eu antibody

10

5μL

25μL

125μL

500μL

-80℃

Anti-Tag2 Ac antibody

25×

20μL

100μL

500μL

2000μL

-80℃

Detection buffer

10×

400μL

2mL

10mL

40mL

-80℃


Note: Aliquot all components immediately after first thawing and store at the recommended temperature. Avoid storage after dilution and repeated freeze-thaw cycles.

```

Protocol

1. Reagent Preparation

1.1 Before use, thaw all reagents at room temperature (equilibrate at room temperature for at least 30 min). The reaction volume for a 384-well shallow well plate is 20 μL (reagent volumes for the reaction system are shown in the table). Calculate the required volume before preparation and prepare as needed; the following preparation is for reference only, using 500 tests as an example.

Table 1. Reagent Preparation

Reagent Name

Preparation

Volume per Detection Well (μL)

Detection buffer

Add 2 mL of 10× Detection buffer 1 to 18 mL of deionized water, dilute to 1×, mix well, and set aside.

-

XZ739

According to the reaction system, dilute the compound to the desired concentration using 1× Detection buffer.

2

Tag1-CRBN protein

Take 40 μL of Tag1-CRBN protein stock solution, dilute to 2 mL with 1× Detection buffer, mix well, and set aside.

4

Tag2- BCL-XL protein

Take 20 μL of Tag2-BCL-XL protein stock solution, dilute to 2 mL with 1× Detection buffer, mix well, and set aside.

4

Antibody Mix

Take 25 μL of Anti-Tag1 Eu antibody stock solution, add 2.475 mL of 1× Detection buffer, mix well; take 100 μL of Anti-Tag2 Ac antibody stock solution, add 2.4 mL of 1× Detection buffer, mix well; mix both solutions 1:1 to prepare the Antibody Mix.

10


1.2 Gradient Dilution of Test Samples

Using XZ739 as an example, the diluent is 1× Detection buffer. To minimize matrix effect interference, it is recommended to dilute with a solution matching the test sample matrix; adjust the test samples according to actual concentrations.

Table 2. XZ739 Gradient Dilution (Adjust According to Actual Conditions)

XZ739 Final Concentration (nM)

XZ739 Preparation Concentration (nM)

Preparation Method

10000

100000

1μL 4mM XZ739 +39μL 1× Detection buffer

5000

50000

20μL ① +20μL 1× Detection buffer

2500

25000

20μL ② +20μL 1× Detection buffer

1250

12500

20μL ③ +20μL 1× Detection buffer

625

6250

20μL ④ +20μL 1× Detection buffer

312.50

3125

20μL ⑤ +20μL 1× Detection buffer

156.25

1562.50

20μL ⑥ +20μL 1× Detection buffer

78.13

781.25

20μL ⑦+20μL 1× Detection buffer

39.06

390.63

20μL ⑧+20μL 1× Detection buffer

19.53

195.31

20μL ⑨+20μL 1× Detection buffer

9.77

97.66

20μL ⑩+20μL 1× Detection buffer

Blank

0

0

20μL 1× Detection buffer


2. Sample Addition and Controls

2.1 Test Samples: Add 4 μL Tag1-CRBN protein working solution, 4 μL Tag2-BCL-XL protein working solution, 2 μL gradient-diluted test samples, and 10 μL mixed Antibody Mix sequentially into the 384-well shallow well plate.

2.2 Positive Control Standard Curve: 4 μL Tag1-CRBN protein working solution, 4 μL Tag2-BCL-XL protein working solution, 2 μL gradient-diluted XZ739, and 10 μL Antibody Mix.

2.3 Blank Control Wells: Replace test samples with 2 μL 1× Detection buffer;

2.4 NC (Negative Control): Add 10 μL 1× Detection buffer and 10 μL Antibody Mix.

After adding all samples, centrifuge, seal with a plate sealing film, and incubate at room temperature for 2 hours.

3. Detection

Positive Control Standard Curve

Test Samples

Blank Control Wells

NC

2 μL

Gradient-diluted XZ739

2 μL

Gradient-diluted test samples

2 μL

1× Detection buffer

10 μL 1× Detection buffer

Add 10 μL Antibody Mix

4 μL Tag1-CRBN protein

4 μL Tag2-BCL-XL protein

10 μL Antibody Mix

Seal the plate wells with a sealing film , and incubate at room temperature for 2 hours;


Detect using a microplate reader compatible with TR-FRET. Excitation wavelength is 320/340 nm, and emission wavelengths detected are 620 nm and 665 nm.

[Result Calculation]

1) Calculate signal value (Ratio): Divide the fluorescence signal at 665 nm by the signal at 620 nm, then multiply by 10000.

Ratio = (665/620) ×10000

2) Calculate Net signal based on the signal value:

Net signal = (Std-NC)/NC×100

3) Calculate CV (%):

CV(%)= Standard Deviation/Mean Ratio × 100%

[Data Example]

The following data cannot replace experimental results and is provided only as an example; results may vary depending on the plate reader used.

3 /3Note: Recommended microplates (384-well, white, shallow well);

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 32349616917

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.0 ★★★★★
Based on 7 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
K
Verified Purchase
Katherine
West Palm Beach, US
★★★★★ 5
Great suit!
Color: Black, Size: Medium
Looks super nice! For the price, it is definitely worth it. The fabric looks and feels great and the size range is good.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 9, 2026
K
Verified Purchase
Kia
West Palm Beach, US
★★★★★ 5
​Perfect for a wedding! Everyone loved it
Color: Deep Blue, Size: XX-Large
​I bought this suit set for our wedding and it was a huge hit everyone loved how it looked! The slim fit is perfect and looks very sharp and modern. The material is great quality and it comes with everything you need, making it an incredible value. My kids got compliments all night!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 20, 2026
S
Verified Purchase
S Perez
Carnegie, US
★★★★★ 5
Great quality
Color: Black, Size: X-Small
Fit my son perfect. Ordered XS he’s 5’5” 128 lbs. pants fit great, they weren’t too big or too long. He felt comfortable and got many complements. Tie color comes random not black like the picture.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 19, 2026
T
Verified Purchase
Travis Avery
Lake Worth, US
★★★★★ 4
Waist is big. I weigh 238lbs. And got what said was 215-230lb.
Color: Black, Size: XX-Large
Everything fits good, except the waist was about 2-3 sizes to big.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 10, 2026
M
Verified Purchase
monica hudgins
Lowell, US
★★★★★ 5
Great price
Color: Black, Size: 12
This suit was super cute fit my son well only sent it back because one of the seam was coming undone. I did re-order it with a replacement.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 25, 2026

recommand products