Pay in installments of $48.25 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 28 - Aug 2
For Your Every Summer RSVP, with Code: SUMMER15
Description
TEKTELIC BREEZE — LoRaWAN Indoor Air Quality SensorTEKTELIC at INNON BREEZE IAQ Sensor Technical Documents Everything you need before and after commissioning. Spec sheet, user guide, and integration resources all hosted directly so you can share links with your team or drop them into your project documentation. Spec Sheet CO2 range, humidity accuracy, dimensions, battery life, RF performance. Download PDF User Guide Commissioning guide mounting, LoRaWAN onboarding, tick configuration, CO2 calibration.
← TEKTELIC at INNON® / BREEZE IAQ Sensor
Technical Documents
Everything you need before and after commissioning.
Spec sheet, user guide, and integration resources — all hosted directly so you can share links with your team or drop them into your project documentation.
Spec Sheet
CO2 range, humidity accuracy, dimensions, battery life, RF performance.
Download PDF →
User Guide
Commissioning guide — mounting, LoRaWAN onboarding, tick configuration, CO2 calibration.
Download PDF →
INNON® Integration Guide
Niagara 4 integration — BACnet object mapping, calibration intervals, threshold alerts.
Ask our team →
Missing a document?
CE declarations, LoRa Alliance certifications, and firmware release notes available on request.
A Ready For Anything® building block
One wireless sensor that gives your BMS the data it needs to control ventilation based on actual air quality — not a timer.
CO2 (NDIR) · Temperature · Humidity · VOC · Light · 10-year battery · CF25 compliant
The problem this product exists to solve
Most ventilation systems in occupied buildings run on a time schedule. They come on at 8am, go off at 6pm, and run at the same rate regardless of whether the room has 30 people in it or nobody. That's a significant energy waste — and in schools, hospitals, and office buildings, it's also a health risk.
CO2 above 1,000ppm in a classroom directly affects cognitive performance. Studies are clear on this. The problem has always been measurement — running a cable to every room for a wired CO2 sensor is expensive and disruptive on a retrofit.
The BREEZE removes the cable run. It's LoRaWAN — mount it on the wall in 10 minutes, no conduit, no chasing. Your gateway picks up the signal and outputs CO2, temperature, humidity, light, and barometric pressure as BACnet objects. Niagara sees them and can control your HVAC accordingly.
A few things worth knowing before you deploy
- Automatic CO2 self-calibration every 7 days — the BREEZE recalibrates its CO2 baseline automatically on a configurable schedule (7 days by default); no manual intervention, no drift over time, no site visit to reset the sensor after installation
- Barometric pressure compensation built in — CO2 readings are corrected for altitude and local air pressure; if you are deploying across multiple floors or at different site elevations, the readings are accurate without manual offset calibration
- Wall, ceiling, or table mount — three mounting configurations out of the box; no additional hardware required for different room types or furniture layouts
- Sensor and display can be separated — the BREEZE sensor is positioned at the correct measurement height while the E-Ink display goes where occupants can actually read it; the two do not need to be co-located
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy